MT-PAnnual Maintenance & Readiness Contracts
Fire pumps: maintenance and testing so the pressure is there when it's needed
The fire pump gives sprinklers and hoses the pressure and flow they need; if it fails, the whole system fails. We inspect and run pumps on schedule, carry out and record the annual flow test, and maintain controllers, diesel drivers and the jockey pump under the annual maintenance contract.

At a glance
- Provided by
- Osool Al-Salama Fire Systems & Contracting, an engineering company in Al Khobar since 2011
- Where
- The Eastern Province: Al Khobar, Dammam, Dhahran, Jubail and Al Ahsa, from our office in Al Khobar
- For
- Buildings, warehouses, factories, hospitals and compounds with a fire pump room and a firefighting water tank
What's in a fire pump room
Electric fire pump
The main pump at most sites; starts automatically when the network pressure drops.
Diesel fire pump
The back-up that runs if the power fails; it needs fuel, batteries and cooling always ready.
Jockey pumpJockey
A small pump that keeps the network pressurised and makes up minor leaks, so the main pump doesn't start for nothing.
Controller
Starts the pump automatically and shows alarms such as power loss or failure to start; its settings decide when each pump runs.
What the rules and standards say
- 01
The Civil Defense safety licence application includes a valid maintenance contract for the safety systems, depending on the activity.
المديرية العامة للدفاع المدني: خدمة ترخيص السلامة - 02
Stationary fire pumps are installed to NFPA 20.
NFPA 20: Standard for the Installation of Stationary Pumps for Fire Protection - 03
NFPA 25 sets routine pump checks and tests: no-flow runs at regular intervals (weekly for diesel pumps) and an annual flow test that compares performance with the pump curve.
NFPA 25: Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems
03What the pump maintenance contract covers
- Scheduled visits: pumps run, pressures read, leaks and valves checked
- Controller and start/stop settings of the main and jockey pumps checked
- Diesel driver upkeep: fuel, batteries, oil and cooling
- The annual flow test, with a written report and recorded readings
- Breakdown and emergency visits for contracted sites
What the site manager should watch between visits
Simple checks that catch problems early:
- No alarms on the controller, pumps left in automatic.
- Diesel fuel and the water tank at the required levels.
- Network valves open and secured.
- If the main pump keeps starting on its own, there is a leak or a jockey setting problem: tell us.
Questions about this service
Related guides
What does the jockey pump do?
It keeps the firefighting network pressurised and makes up minor leaks, so the main pump only starts on a real demand for water, such as an open sprinkler or hose.
How often is a fire pump tested?
Under NFPA 25: no-flow runs at regular intervals (weekly for diesel pumps; monthly or weekly for electric pumps depending on the case) and an annual flow test against the pump curve. What your site needs is set by Civil Defense and the maintenance contract.
Why does the main fire pump sometimes start by itself?
Usually because network pressure is dropping: a leak in a pipe or valve, or a jockey pump fault or setting. Frequent starts wear the pump, so it's best to find the cause early.
Are fire pumps part of the annual maintenance contract?
Yes. Osool Al-Salama's annual maintenance contract covers fire pumps together with sprinkler, hose, gas and alarm systems, with scheduled visits and breakdown visits for contracted sites.
Let's start with what your facility needs
Send your request and one of our engineers will contact you to discuss the facility and the right systems, then arrange the site survey and quote with you.
- A technical consultation or a site survey
- A quote for a new project or an existing building
- A maintenance contract for existing systems
Or reach us directly
Request a consultation or a quote
A short form that goes straight to our sales team. No drawings needed at this stage.