Skip to content
Osool Al-Salama Fire Systems & Contracting Co.

02Services

Fire Detection, Alarm & Evacuation

Early detection that buys time to act: intelligent addressable systems that pinpoint the danger, high-sensitivity aspirating detection before smoke is visible, and voice evacuation that leads people out safely.

Smoke detector on a corridor ceiling

At a glance

Service
Fire Detection, Alarm & Evacuation: Early detection that buys time to act: intelligent addressable systems that pinpoint the danger, high-sensitivity aspirating detection before smoke is visible, and voice evacuation that leads people out safely.
Provided by
Osool Al-Salama Fire Systems & Contracting, an engineering company in Al Khobar since 2011
Where
The Eastern Province: Al Khobar, Dammam, Dhahran, Jubail and Al Ahsa, from our office in Al Khobar
For
Commercial and office buildings, hospitals, hotels, warehouses and plants, and existing buildings that need an upgrade
How to start
Send a quote request from this page, message us on WhatsApp, or call us. The facility type and location are enough.

01What we provide

An alarm system is worth what it does in the first minutes. So we work on it at every stage: reviewing design and construction documents for low-current systems, investigating the site, monitoring contractors, running acceptance tests and analysing existing systems to find what needs upgrading before it fails.

  1. 01Design and construction document review
  2. 02Site investigations
  3. 03Contractor performance monitoring
  4. 04Acceptance testing and analysis of existing systems
02Where it works in a facility

Where it works in a facility

  • Intelligent addressable systems that pinpoint the danger
  • Very early warning aspirating detection (VESDA)
  • Voice evacuation and emergency lighting
  • Engineering review and acceptance testing
Illustrative section through a facility showing where protection systems sitFrom basement to roof: fire pumps and water tank, risers, sprinklers, the alarm panel and detectors, a server room with gas-based suppression and early-warning detection, and a kitchen hood system.RF0201GFB101020304050607

Illustrative — not a construction drawing

03Scope of work

Scope of work

As listed in our scope. The right system for each area is chosen after the needs assessment.

01

Detection

  • Intelligent addressable systems
  • High-sensitivity smoke detection
  • Beam detection for large spaces
  • Linear heat detection
  • Wireless fire alarm systems for existing buildings
  • Conventional detection systems
  • Water leak detection

02

Evacuation & life safety

  • Voice evacuation systems
  • Emergency lighting
  • Central battery systems

03

Engineering services

  • Review of design and construction documents for low-current systems
  • Site investigations
  • Contractor performance monitoring
  • System acceptance testing
  • Analysis of existing systems
04What helps before the first conversation

What helps before the first conversation

You don't need all of it. Message us with what you have — we'll cover the rest with you in the chat.

  1. 01Facility type, floors and zones
  2. 02New installation or upgrade of an existing system?
  3. 03Existing system type and brand, for upgrades
  4. 04Drawings or previous inspection reports, if available
What is the difference between addressable and conventional fire alarm systems?

An addressable system identifies every detector individually, so the panel shows exactly which room or point raised the alarm — suited to large and multi-storey buildings. A conventional system splits the building into zones, so you know the zone rather than the device — suited to smaller spaces. We install both and recommend one after the survey.

Can a fire alarm be installed in an existing building without major works?

In many existing buildings a wireless fire alarm system can reduce the cabling needed. That is decided after surveying the building and any system already in place.

How often does a fire alarm system need inspection and testing?

NFPA 72 sets periodic inspection and testing schedules, and many alarm components are tested at least once a year, plus acceptance testing at handover and after any change. The actual schedule for your facility is set in the maintenance contract and by the competent authority's requirements.

Do you test alarm systems installed by another contractor?

Yes. Our engineering services include design and construction document review, contractor performance monitoring, system acceptance testing, and analysis of existing systems to find what needs upgrading.

07Start here

Let's start with what your facility needs

Send your request and one of our engineers will contact you to discuss the facility and the right systems, then arrange the site survey and quote with you.

  • A technical consultation or a site survey
  • A quote for a new project or an existing building
  • A maintenance contract for existing systems

Request a consultation or a quote

A short form that goes straight to our sales team. No drawings needed at this stage.

Facility type, size, or exactly what you need.