Addressable or conventional fire alarm: which one for your building?

A conventional fire alarm splits the building into zones and tells you which zone is in alarm; an addressable system gives every detector an address and names the exact device and location. We choose the right one for the size and use of the building, then design, install, program, test and maintain it.

Smoke detector on a corridor ceiling

At a glance

Provided by
Osool Al-Salama Fire Systems & Contracting, an engineering company in Al Khobar since 2011
Where
The Eastern Province: Al Khobar, Dammam, Dhahran, Jubail and Al Ahsa, from our office in Al Khobar
For
Offices, clinics and shops, multi-storey buildings, hotels and hospitals, warehouses and factories, data centres
01Addressable and conventional fire alarms

The systems we install and when each fits

  • AddressableAddressable

    Each detector has an address, so the panel shows the exact device and location and monitors its condition. Best for large and multi-storey buildings, hotels and hospitals.

  • ConventionalConventional

    Detectors are wired in zones and the panel shows the zone, not the device. Simpler and lower-cost; suits small sites with few zones.

  • Wireless

    Detectors that talk to the panel by radio, for existing or heritage buildings where cabling is hard.

  • Aspirating detectionVESDA

    Draws air samples through pipes and detects smoke before it's visible. For data centres, equipment rooms and high-ceiling warehouses.

02What the rules and standards say

What the rules and standards say

  1. 01

    The Saudi Fire Code SBC 801 sets when a fire alarm is required, by the building's use, area and occupancy.

    الكود السعودي للحماية من الحرائق SBC 801
  2. 02

    Fire alarms are designed, installed and tested to NFPA 72, which covers detector and notification layout and secondary power.

    NFPA 72: National Fire Alarm and Signaling Code
  3. 03
  4. 04

    What your premises specifically need shows on Salamah or at the Civil Defense inspection.

    منصة سلامة

03What we provide

  • The right system chosen, and the detector and sounder layout designed
  • Panel, detectors, sounders and manual call points supplied
  • Installation, programming and the cause-and-effect matrix (what happens on each alarm)
  • Interfaces with gas suppression, lifts, HVAC and doors
  • Acceptance testing, and review and analysis of existing systems
  • Periodic inspection and testing under the annual maintenance contract
04Inspection and upkeep

Inspection and upkeep

Common practice under NFPA 72; what your site needs is set by Civil Defense:

  • A yearly test of every detector, call point, sounder and the panel.
  • Batteries and the secondary power supply checked regularly.
  • Any fault or false alarm dealt with as it appears, and logged.
  • Detector layout reviewed when walls or the use of a space change.
What's the difference between addressable and conventional fire alarms?

A conventional system splits the building into zones: the panel tells you the zone, and you then look for the detector. An addressable system gives each detector an address, so the panel shows the exact device and location, and it monitors every device for faults. Addressable is more precise and easier to maintain in large buildings; conventional is simpler and cheaper for small sites.

Which one suits my building?

A shop, clinic or small office with few zones usually suits a conventional system. Multi-storey buildings, hotels, hospitals and large warehouses suit addressable. The approved design and Civil Defense requirements have the final word. Send us the type, area and floors and we'll recommend one.

Can a conventional system be upgraded to addressable?

Yes, by replacing the panel and detectors. The existing cabling can sometimes be reused if it suits the new system; we confirm that after surveying and testing the system.

What is VESDA and when do I need it?

VESDA is a very early warning system that draws air samples through pipes and analyses them, detecting smoke before ordinary detectors would. It's used in data centres, sensitive equipment rooms and high-ceiling warehouses.

Do you test fire alarms installed by others?

Yes. Analysing existing systems and acceptance testing are part of our scope. We test the system, give you a report on its condition and what it needs, and add it to a maintenance contract if you wish.

07Start here

Let's start with what your facility needs

Send your request and one of our engineers will contact you to discuss the facility and the right systems, then arrange the site survey and quote with you.

  • A technical consultation or a site survey
  • A quote for a new project or an existing building
  • A maintenance contract for existing systems